Surveillance for early silicosis in high altitude miners using pulse oximetry

Int J Occup Environ Health. 2008 Jul-Sep;14(3):187-92. doi: 10.1179/oeh.2008.14.3.187.

Abstract

Two cross-sectional studies in a high altitude region of Perú evaluated the role of pulse oximetry for detection of silicosis in high-altitude miners. In study one, exercise pulse oximetry and chest radiographs were used to evaluate 343 silica-exposed miners and 141 unexposed subjects for evidence of silicosis. Study 2 investigated the association between exercise oxygen saturation and silicosis in 32 non-silicotic and 65 silicotic miners. In study one, age (Odds Ratio [OR] 1.10, 95% Cofidence Interval (CI) 1.07-1.12) and resting oxygen saturation (OR 0.95, 95%CI 0.90-0.99) were associated with silicosis. In study two, years of mining employment (OR 1.14, 95%CI 1.05-1.23) and exercise oxygen saturation at 30% maximum heart rate (OR 0.86, 95%CI 0.75-0.99) were associated with silicosis. Hypoxemia at rest and with exercise is associated with silicosis in high altitude miners. Pulse oximetry should be further investigated as a screening tool for silicosis at high altitudes.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Altitude*
  • Confidence Intervals
  • Cross-Sectional Studies
  • Humans
  • Mining*
  • Occupational Exposure
  • Oximetry* / instrumentation
  • Peru
  • Silicosis / diagnosis*
  • Surveys and Questionnaires