Evaluation of compliance with a paper-based, multiplication-factor, intravenous insulin protocol

Ann Pharmacother. 2009 Sep;43(9):1413-8. doi: 10.1345/aph.1M060. Epub 2009 Aug 4.

Abstract

Background: Hyperglycemia is common in critically ill patients and is an independent risk factor for in-hospital morbidity and mortality.

Objective: To assess compliance with a paper-based, multiplication-factor, intravenous insulin protocol.

Methods: A retrospective chart review was conducted in a 720-bed urban, academic medical center in Boston, Massachusetts. During a 1-month period, compliance with and the consequent safety and efficacy of the Brigham and Women's Hospital paper-based, multiplication-factor, intravenous insulin protocol was evaluated.

Results: The primary endpoint of protocol compliance, defined as correct adjustment to insulin infusion rate and correct timing of bedside blood glucose concentration (BBGC) checks +/-10 minutes of prespecified BBGC check according to the Brigham and Women's Hospital Intravenous Insulin Protocol (BHIP), was 47.2%. Seventy-two patients met inclusion criteria. Appropriate adjustment of infusion rates occurred 68.2% (1206/1768) of the time. Compliance with the timing of BBGC checks was found to be the majority of protocol violations. BBGCs were monitored +/-5 minutes of indicated time per the protocol 26.2% (463/1768) of the time. Blood glucose concentration checks within extended timing of +/-10 minutes of indicated time per the protocol occurred 793 (44.8%) times. Blood glucose concentration monitoring took place greater than 20 minutes past indicated time 450 (25.5%) times. In 1768 measurements, blood glucose concentrations between 40 and 60 mg/dL occurred 23 (1.3%) times in 12 (16.7%) patients. Blood glucose concentrations 40 mg/dL or less were detected 3 (0.17%) times in 2 (2.7%) patients. None of these hypoglycemic events led to documented complications.

Conclusions: Overall, a rather low level of compliance with a paper-based, multiplication-factor, intravenous insulin protocol was observed, which warrants further investigation. Compliance rates in this evaluation were found to be similar to the rates observed in previously evaluated fixed-dose intravenous insulin protocols. Protocol noncompliance may be associated with hypo- and hyperglycemia.

MeSH terms

  • Academic Medical Centers
  • Adult
  • Aged
  • Aged, 80 and over
  • Blood Glucose / analysis
  • Blood Glucose / drug effects
  • Critical Care / standards
  • Critical Illness*
  • Female
  • Guideline Adherence
  • Humans
  • Hyperglycemia / drug therapy*
  • Hypoglycemic Agents / administration & dosage*
  • Hypoglycemic Agents / therapeutic use
  • Infusions, Intravenous
  • Insulin / administration & dosage*
  • Insulin / therapeutic use
  • Male
  • Middle Aged
  • Practice Guidelines as Topic
  • Retrospective Studies
  • Time Factors

Substances

  • Blood Glucose
  • Hypoglycemic Agents
  • Insulin