Contact lens-related adverse events and the silicone hydrogel lenses and daily wear care system used

Arch Ophthalmol. 2009 Dec;127(12):1616-23. doi: 10.1001/archophthalmol.2009.313.

Abstract

Objective: To investigate the incidence of adverse events related to the use of varying silicone hydrogel contact lens and lens solution combinations.

Methods: Individuals with myopia (N = 558) participated in 1 or more of approximately 40-participant trials in a matrix of 20 silicone hydrogel contact lens and lens-solution combinations. Visits were at baseline, 2 weeks, 1 month, and 3 months. The mean study completion rate was 90% of the expected participant-months (final data set: 840 lens-solution combinations and 2271 participant-months). Adverse events were reported as the first occurrence of each type per 100 participant-months for each lens-solution combination.

Results: The rate of all corneal infiltrative events (CIEs) was 3.1 per 100 participant-months (range, 0-10.5), and the rate of symptomatic CIEs was 1.7 per 100 participant-months (range, 0-10.5), including 1 case of microbial keratitis (0.04 per 100 participant-months). Rates for CIEs differed substantially among solution groups, with hydrogen peroxide having the lowest rate (0.6 per 100 participant-months; range, 0-0.9). The rate was 0.8 per 100 participant-months (range, 0-8.0) for superior epithelial arcuate lesions, which varied by lens type, 0.04 per 100 participant-months (1 case only) for corneal erosion, and 0.4 per 100 participant-months (range, 0-2.0) for contact lens papillary conjunctivitis, which was modified by type of solution. The rate of solution-induced corneal staining for all lens-solution combinations was 4.7 per 100 participant-months (range, 0-23) and varied significantly based on lens-solution combination (P < .001).

Conclusions: The frequency of adverse events varied with silicone hydrogel contact lens and lens solution combinations, with hydrogen peroxide having the lowest incidence of CIEs and solution-induced corneal staining, indicating that lens material and design, type of solution, and solution-lens interactions are likely contributing factors in this mode of lens wear.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Contact Lens Solutions
  • Contact Lenses, Hydrophilic / adverse effects*
  • Corneal Diseases / epidemiology
  • Corneal Diseases / etiology
  • Female
  • Humans
  • Hydrogels*
  • Incidence
  • Male
  • Myopia / therapy*
  • Refraction, Ocular / physiology
  • Silicones*
  • Visual Acuity / physiology
  • Young Adult

Substances

  • Contact Lens Solutions
  • Hydrogels
  • Silicones