Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department

Acad Emerg Med. 2015 Nov;22(11):1298-306. doi: 10.1111/acem.12814. Epub 2015 Oct 16.

Abstract

Objectives: The objective was to compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED).

Methods: This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared.

Results: Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159 and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% confidence interval [CI] = 72.1% to 73.4%) and specificity of 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity of 92.1% (95% CI = 91.7% to 92.4%) and specificity of 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment versus algorithmic alert were 40.3% versus 2.5% and 99.88% versus 99.96%, respectively.

Conclusions: The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities.

Publication types

  • Observational Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Adolescent
  • Algorithms*
  • Child
  • Child, Preschool
  • Clinical Decision-Making*
  • Consensus
  • Emergency Service, Hospital / statistics & numerical data*
  • Female
  • Fever / epidemiology
  • Hospitals, Pediatric*
  • Humans
  • Hypothermia / epidemiology
  • Infant
  • Male
  • ROC Curve
  • Retrospective Studies
  • Sensitivity and Specificity
  • Sepsis / diagnosis*
  • Shock, Septic / diagnosis