Effect of pulsed xenon ultraviolet room disinfection devices on microbial counts for methicillin-resistant Staphylococcus aureus and aerobic bacterial colonies

Am J Infect Control. 2018 Jun;46(6):668-673. doi: 10.1016/j.ajic.2018.02.001. Epub 2018 Apr 11.

Abstract

Background: Inadequate environmental disinfection represents a serious risk for health care-associated infections. Technologic advancements in disinfection practices, including no-touch devices, offer significant promise to improve infection control. We evaluated one such device, portable pulsed xenon ultraviolet (PX-UV) units, on microbial burden during an implementation trial across 4 Veterans Affairs hospitals.

Methods: Environmental samples were collected before and after terminal room cleaning: 2 facilities incorporated PX-UV disinfection into their cleaning protocols and 2 practiced manual disinfection only. Specimens from 5 high-touch surfaces were collected from rooms harboring methicillin-resistant Staphylococcus aureus (MRSA) or aerobic bacteria colonies (ABC). Unadjusted pre-post count reductions and negative binomial regression modeled PX-UV versus manual cleaning alone.

Results: Seventy samples were collected. Overall, PX-UV reduced MRSA and ABC counts by 75.3% and 84.1%, respectively, versus only 25%-30% at control sites. Adjusting for baseline counts, manually cleaned rooms had significantly higher residual levels than PX-UV sites. Combined analyses revealed an incident rate ratio of 5.32 (P = .0024), with bedrails, tray tables, and toilet handrails also showing statistically superior PX-UV disinfection.

Conclusions: This multicenter study demonstrates significantly reduced disinfection across several common pathogens in facilities using PX-UV devices. Clinical impact of laboratory reductions on infection rates was not assessed, representing a critical future research question. However, such approaches to routine cleaning suggest a practical strategy when integrated into daily hospital operations.

Keywords: Hospital-associated infections; aerobic colonies; implementation; methicillin-resistant Staphylococcus aureus; no-touch disinfection.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Anesthetics, Inhalation
  • Bacteria, Aerobic / isolation & purification*
  • Bacteria, Aerobic / radiation effects
  • Colony Count, Microbial
  • Disinfection / methods*
  • Environmental Microbiology*
  • Hospitals, Veterans
  • Humans
  • Methicillin-Resistant Staphylococcus aureus / isolation & purification*
  • Methicillin-Resistant Staphylococcus aureus / radiation effects
  • Microbial Viability / radiation effects
  • Ultraviolet Rays*
  • Xenon*

Substances

  • Anesthetics, Inhalation
  • Xenon