Development and pilot evaluation of an electronic health record usability and safety self-assessment tool

JAMIA Open. 2022 Jul 30;5(3):ooac070. doi: 10.1093/jamiaopen/ooac070. eCollection 2022 Oct.

Abstract

Objective: Poor electronic health record (EHR) usability contributes to clinician burnout and poses patent safety risks. Site-specific customization and configuration of EHRs require individual EHR system usability and safety testing which is resource intensive. We developed and pilot-tested a self-administered EHR usability and safety assessment tool, focused on computerized provider order entry (CPOE), which can be used by any facility to identify specific issues. In addition, the tool provides recommendations for improvement.

Materials and methods: An assessment tool consisting of 104 questions was developed and pilot-tested at 2 hospitals, one using a Cerner EHR and the other using Epic. Five physicians at each site participated in and completed the assessment. Participant response accuracy compared to actual EHR interactions, consistency across participants, and usability issues identified through the tool were measured at each site.

Results: Across sites, participants answered an average of 46 questions in 23 min with 89.9% of responses either correct or partially correct. The tool identified 8 usability and safety issues at one site and 7 at the other site across medication, laboratory, and radiology CPOE functions.

Discussion: The tool shows promise as a method to rapidly evaluate EHR usability and safety and provide guidance on specific areas for improvement. Important improvements to the evaluation tool were identified including the need to clarify certain questions and provide definitions for usability terminology.

Conclusion: A self-administered usability and safety assessment tool can serve to identify specific usability and safety issues in the EHR and provide guidance for improvements.

Keywords: electronic health record; patient safety; usability.