Index Surgery Cost of Fluoroscopic Freehand Versus Robotic-Assisted Pedicle Screw Placement in Lumbar Instrumentation: An Age, Sex, and Approach-Matched Cohort Comparison

J Am Acad Orthop Surg Glob Res Rev. 2022 Dec 2;6(12):e22.00137. doi: 10.5435/JAAOSGlobal-D-22-00137. eCollection 2022 Dec 1.

Abstract

Background: Spine surgery costs are notoriously high, and there are already criticisms and concerns over the economic effects. There is no consensus on cost variation with robot-assisted spine fusion (rLF) compared with a manual fluoroscopic freehand (fLF) approach. This study looks to compare the early costs between the robotic method and the freehand method in lumbar spine fusion.

Methods: rLFs by one spine surgeon were age, sex, and approach-matched to fLF procedures by another spine surgeon. Variable direct costs, readmissions, and revision surgeries within 90 days were reviewed and compared.

Results: Thirty-nine rLFs were matched to 39 fLF procedures. No significant differences were observed in clinical outcomes. rLF had higher total encounter costs (P < 0.001) and day-of-surgery costs (P = 0.005). Increased costs were mostly because of increased supply cost (0.0183) and operating room time cost (P < 0.001). Linear regression showed a positive relationship with operating room time and cost in rLF (P < 0.001).

Conclusion: rLF is associated with a higher index surgery cost. The main factor driving increased cost is supply costs, with other variables too small in difference to make a notable financial effect. rLF will become more common, and other institutions may need to take a closer financial look at this more novel instrumentation before adoption.

MeSH terms

  • Cohort Studies
  • Costs and Cost Analysis
  • Female
  • Fluoroscopy* / economics
  • Fluoroscopy* / methods
  • Humans
  • Lumbar Vertebrae* / surgery
  • Male
  • Pedicle Screws
  • Robotic Surgical Procedures* / economics
  • Robotic Surgical Procedures* / methods