Midline catheters in patients with advanced chronic kidney disease

J Hosp Med. 2023 Nov;18(11):969-977. doi: 10.1002/jhm.13209. Epub 2023 Sep 29.

Abstract

Background: Midline catheters (midlines) are increasingly used in patients with advanced chronic kidney disease (CKD).

Objective: This study describes current practice and acute complications associated with midlines in CKD patients.

Designs, setting, and participants: Trained abstractors at 66 hospitals from the Michigan Hospital Medicine Safety (HMS) Consortium collected data on a sample of patients who received a midline during hospitalization. Patients were classified as having advanced CKD if their estimated glomerular filtration rate was <45 mL/min/1.73 m2 .

Main outcome and measures: Midline recipients with advanced CKD were compared to those without advanced CKD by patient, provider, and device characteristics, and by the occurrence of acute complications including major (e.g., upper extremity deep vein thrombosis [UE-DVT] and catheter-related bloodstream infection [CRBSI]) or minor (e.g., catheter occlusion, catheter dislodgement, infiltration, superficial thrombophlebitis, and leaking at insertion site) events. Multivariable mixed effects logistic regression was used to evaluate the association between catheter-related complications and stage of CKD.

Results: Of 21,415 midline recipients, 5272 (24.6%) had advanced CKD, while 16,143 (75.4%) did not. Most midlines were single lumen (90.5%) and remained in place for a median of 6 days. A major or minor midline complication occurred in 804 (15.3%) patients with and 2239 (14.4%) patients without advanced CKD (adjusted odds ratios = 1.04; 95% confidence interval: 0.94-1.14). Among patients with advanced CKD, CRBSI occurred in 13 patients (0.2%) and UE-DVT occurred in 65 patients (1.2%). The proportion of advanced CKD among midline recipients and the frequency of midline-related complications varied across hospitals (interquartile range [IQR] = 19.2% to 29.8% [median = 25.0%] and IQR = 11.0%-18.9% [median = 15.4%], respectively).

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Catheterization, Central Venous* / adverse effects
  • Catheters
  • Humans
  • Patients
  • Postoperative Complications / etiology
  • Renal Insufficiency, Chronic*
  • Thrombophlebitis*