Self-collection of samples for group B streptococcus testing during pregnancy: a systematic review and meta-analysis

BMC Med. 2023 Dec 18;21(1):498. doi: 10.1186/s12916-023-03186-x.

Abstract

Background: Sample self-collection for reproductive tract infection diagnosis has been found to offer greater convenience, privacy, autonomy, and expanded access to testing in non-pregnant adults. This review aimed to determine whether sample self-collection is as accurate as provider-collection for detection of group B streptococcus colonisation in pregnancy and whether a strategy of self-collection compared to provider-collection might improve maternal and neonatal health outcomes.

Methods: We searched CINAHL Plus, Medline, EMBASE, Maternity and Infant Care Database, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews in June 2022. Eligible studies compared self-collected and provider-collected samples taken from the same participants or participants randomised to either self-collection or provider-collection for reproductive tract infection testing using the same test and testing method in pregnant individuals. We included trials and observational studies. Reviewers assessed risk of bias using the QUADAS-2 checklist and independently extracted data. Sensitivity and specificity for group B streptococcus colonisation of self-collected compared to provider-collected samples were pooled using a bivariate, random-effects, meta-analytic model. This review was registered with PROSPERO (CRD42023396573).

Results: The search identified 5909 references, of which eleven diagnostic accuracy group B streptococcus studies were included (n = 3269 participants). No studies assessed the effects of self-collection in pregnancy on health outcomes. All studies had high or unclear risk of bias. Pooled sensitivities of self-collected samples for group B streptococcus detection were 82% (95% CI: 66-91%; I2 = 68.85%) in four trials (n = 1226) and 91% (95% CI: 83-96%; I2 = 37.38%) in seven non-randomised studies (n = 2043). Pooled specificities were 99% (95% CI: 98-99%; I2 = 12.08%) and 97% (95% CI: 94-99%; I2 = 72.50%), respectively.

Conclusions: Self-collected samples for group B streptococcus detection in pregnancy had high specificity compared to provider-collection, but lower sensitivity, particularly for included trials. Studies investigating the effect of self-collection on health outcomes, and further higher quality trials comparing accuracy of self-collection to provider-collection, are required.

Keywords: Antenatal; Diagnostic accuracy; GBS; Group B strep; Group B streptococcal infection; Group B streptococcus; Pregnancy; Self-care; Self-care intervention; Self-sampling.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Adult
  • Female
  • Humans
  • Infant, Newborn
  • Pregnancy
  • Reproductive Tract Infections*
  • Streptococcus