Cost-effectiveness analysis of transcatheter aortic valve implantation in aortic stenosis patients at low- and intermediate-surgical risk in Japan

J Med Econ. 2024 Jan-Dec;27(1):697-707. doi: 10.1080/13696998.2024.2346397. Epub 2024 May 6.

Abstract

Objective: To analyze the cost-effectiveness of transcatheter aortic valve implantation (TAVI) using the SAPIEN 3 (Edwards Lifesciences, Irvine, CA) compared to surgical aortic valve replacement (SAVR) in low- and intermediate-risk patients from a Japanese public healthcare payer perspective.

Methods: A Markov model cost-effectiveness analysis was developed. Clinical and utility data were extracted from a systematic literature review. Cost inputs were obtained from analysis of the Medical Data Vision claims database and supplemented with a targeted literature search. The robustness of the results was assessed using sensitivity analyses. Scenario analyses were performed to determine the impact of lower mean age (77.5 years) and the effect of two different long-term mortality hazard ratios (TAVI versus SAVR: 0.9-1.09) on both risk-level populations. This analysis was conducted according to the guidelines for cost-effectiveness evaluation in Japan from Core 2 Health.

Results: In intermediate-risk patients, TAVI was a dominant procedure (TAVI had lower cost and higher effectiveness). In low-risk patients, the incremental cost effectiveness ratio (ICER) for TAVI was ¥750,417/quality-adjusted-life-years (QALY), which was below the cost-effectiveness threshold of ¥5 million/QALY. The ICER for TAVI was robust to all tested sensitivity and scenario analyses.

Conclusions: TAVI was dominant and cost-effective compared to SAVR in intermediate- and low-risk patients, respectively. These results suggest that TAVI can provide meaningful value to Japanese patients relative to SAVR, at a reasonable incremental cost for patients at low surgical risk and potentially resulting in cost-savings in patients at intermediate surgical risk.

Keywords: Aortic stenosis; I; I00; I1; I10; I13; Japan; cost utility analysis; incremental cost-effectiveness ratio; transcatheter aortic valve replacement.

Plain language summary

Aortic Stenosis (AS) is the most common valvular heart disease in Japan, and, if left untreated, severe symptomatic AS (sSAS) is associated with a dramatic increase in mortality and morbidity. Transcatheter Aortic Valve Implantation (TAVI) is a minimally invasive treatment option for replacing the aortic valve in patients with sSAS and has been associated with similar or better outcomes compared to Surgical Aortic Valve Replacement (SAVR), which involves open-heart surgical replacement of the aortic valve. The objective of this study was to compare the costs and health outcomes associated with TAVI compared to SAVR in Japanese patients deemed low- or intermediate-risk for surgery. Despite the expanding use of TAVI in Japan, a cost-effectiveness analysis (CEA) does not exist that evaluates the economics of TAVI with the current generation SAPIEN 3 implant in patients with low- and intermediate-risk from a public perspective. Our study suggests that TAVI represents strong value for money among low- and intermediate-risk patients in Japan: compared to SAVR, TAVI is associated with better clinical outcomes and quality of life for patients, at a reasonable additional cost for low-risk patients and at a lower cost for intermediate-risk patients.

MeSH terms

  • Age Factors
  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis* / economics
  • Aortic Valve Stenosis* / surgery
  • Cost-Benefit Analysis*
  • Cost-Effectiveness Analysis
  • Female
  • Heart Valve Prosthesis Implantation / economics
  • Heart Valve Prosthesis Implantation / methods
  • Humans
  • Japan
  • Male
  • Markov Chains*
  • Models, Econometric
  • Quality-Adjusted Life Years*
  • Risk Assessment
  • Transcatheter Aortic Valve Replacement* / economics
  • Transcatheter Aortic Valve Replacement* / methods