Derivation of Stroke Volume from Pulmonary Artery Pressures

Cardiol Ther. 2024 Jun;13(2):401-413. doi: 10.1007/s40119-024-00360-x. Epub 2024 Apr 25.

Abstract

Introduction: Intermittent cardiac output (CO) studies using thermodilution are considered the gold standard. We have developed a stroke volume (SV) calculator from pulmonary pulse pressure (PP) to allow continuous monitoring of SV and CO from PP.

Methods: Hemodynamic data on 169 patients following orthotopic heart transplantation were used to compare our calculator-derived SV (and SV index, or SVi) against thermodilution-derived SV on admission into intensive care unit immediately following heart transplantation (T0) and 6 h after admission (T6).

Results: The calculated SV correlated with thermodilution-derived SV T0 (r = 0.920, p < 0.001, coefficient of 0.539 and the constant of 2.06). The median calculator SV, adjusted for coefficient and constant, was 48.4 ml (37.7, 60.7), comparable to the median thermodilution-derived SV 47.9 ml (37.5, 61.0), p = 0.737 with acceptable agreement on Bland-Altman plots. The thermodilution-derived SVi was 28.1 ml (19.7, 38.7) and adjusted calculator-derived SVi 28.9 ml (19.7, 39.9), p = 0.781. At T6, median thermodilution-derived SVi was 27.7 ml (19.5, 35.9) compared to the calculator-derived SVi median of 26.1 ml (17.7, 37.7), p = 0.203.

Conclusions: Changes in PP can be used to track changes in SV using this calculator. Changes in PP may be used to assess response to treatment in the early post-operative period.

Keywords: Cardiac output; Hemodynamic monitoring; Pulmonary artery pressure.