Hemodialysis Catheter-Associated Right Atrial Thrombus Diagnosed via Point of Care Transesophageal Echocardiogram

POCUS J. 2024 Apr 22;9(1):25-28. doi: 10.24908/pocus.v9i1.16895. eCollection 2024.

Abstract

Catheter-associated right atrial thrombus (CRAT) is a potential complication of central venous catheter placement and is associated with an increase in morbidity and mortality. The precise incidence of CRAT is unknown, and there is a lack of clear screening and management guidelines for this condition. Additionally, the diagnosis is often missed when using transthoracic echocardiography (TTE) alone. Here, we present a case of a 64-year-old female admitted to the medical intensive care unit with multiorgan dysfunction who was diagnosed with hemodialysis catheter-associated right atrial thrombus (HDCRAT) via intensivist-performed point of care transesophageal echocardiography (TEE) after an initial TTE was negative. This patient was successfully treated with systemic anticoagulation, local thrombolysis, and delayed removal of the temporary hemodialysis catheter. Our experience serves to highlight the improved visualization of the right atrium and the diagnostic superiority of HDCRAT with TEE. We suspect that with greater utilization of TEE among intensivists, CRAT and HDCRAT will have increased recognition. It is imperative that intensivists are aware of this complication and various management strategies. Still, more studies are needed to establish clear management guidelines for CRAT and the associated complications.

Keywords: Catheter Associated Right Atrial Thrombus; TEE; Thrombus.

Publication types

  • Case Reports