Comparison of BACTEC 12B vs solid media for the recovery of Mycobacterium avium complex from blood cultures in AIDS patients

Diagn Microbiol Infect Dis. 1997 May;28(1):45-8. doi: 10.1016/s0732-8893(97)89159-6.

Abstract

We compared liquid (BACTEC 12B) and solid culture media for the diagnosis of Mycobacterium avian complex (MAC) bacteremia among 258 AIDS patients with a positive blood culture. Neither culture media alone had adequate sensitivity; BACTEC 12B detected growth earlier. Use of both liquid and solid media may improve the yield of mycobacterial blood culture.

Publication types

  • Comparative Study

MeSH terms

  • AIDS-Related Opportunistic Infections / blood
  • AIDS-Related Opportunistic Infections / microbiology*
  • Bacteriological Techniques
  • Culture Media
  • Evaluation Studies as Topic
  • Humans
  • Mycobacterium avium Complex / growth & development
  • Mycobacterium avium Complex / isolation & purification*
  • Mycobacterium avium-intracellulare Infection / blood
  • Mycobacterium avium-intracellulare Infection / complications
  • Mycobacterium avium-intracellulare Infection / microbiology*
  • Reagent Kits, Diagnostic*
  • Sensitivity and Specificity

Substances

  • Culture Media
  • Reagent Kits, Diagnostic